Non ambering formula. Our most durable two component finish. Formulated for commercial/high traffic areas. Available in Satin, Semi Gloss and Gloss sheens.
SHAKE WELL BEFORE USING. Do not thin. Shake DuraSeal® DuraClear™ Max Floor Finish (Part A) well for 30 seconds prior to adding DuraSeal® DuraClear™ Max Hardener (Part B). One 11 oz. bottle of Hardener will activate one gallon of finish. To activate amounts of finish less than one gallon, use (1) part hardener (Part B) to (10.5) parts finish (Part A). Slowly pour Hardener (Part B) into finish bottle (Part A). Shake mixture for 30-45 seconds then let sit for 5-10 minutes prior to applying. Remove stainless steel screen from the plastic bag and firmly insert the open end of the screen into the large end (bottom) of the spout. The screen should protrude from the bottom of the spout. Insert this entire assembly (screen first) onto the one gallon bottle.
Be certain all material is at room temperature. Use a synthetic T-bar applicator to provide the smoothest finish. Best results are achieved when ambient temperatures are between 50°F and 90°F, and humidity below 80%. NOTE: If applying to white oak, two coats of DuraSeal® DuraClear™ Sealer are recommended.
Light foot traffic is acceptable after 24 hours. Do not expose the finish to rugs, cleaners, spills or heavy traffic for one week. Dry times are based on conditions of 77°F and 50% relative humidity at the recommended application rates.
Tools should be cleaned with warm water.
Apply at 500 sq. ft. per gal.
Use walk-off mats at all entrance doorways to keep dirt and grit to a minimum. Sweep or vacuum daily and damp wipe as needed with DuraSeal® Hardwood Floor Cleaner. Do not use all-purpose cleaner/degreaser products.
The finish/hardener mix must be used within 6 hours after it is mixed. Product properties are diminished after 6 hours. The finish and hardener can only be mixed one time.
Store at room temperature. If stored at high temperature, cool to room temperature before use. Keep from freezing. If frozen, warm to room temperature and mix thoroughly before use.
Do not recap finish/hardener mixture after 6 hours to avoid pressure build up. Allow mixture to completely harden before disposing. Maximum VOC: 275g/L (2.3 lbs.gal). Do not thin.
In case of eye contact, flush thoroughly with large amounts of water. Get medical attention if irritation persists. For skin contact, wash thoroughly with soap and water. If swallowed, call Poison Control Center, hospital emergency room, or physician immediately. This product must be mixed with other components before use. Before opening the packages.
TYPE | SIZE | PROD. NO. | QTY | PDS | GHS SDS |
---|---|---|---|---|---|
FLAT | GAL | 809200000 | 2 | PDS | SDS |
SATIN | GAL | 809100000 | 2 | PDS | SDS |
SEMI-GLOSS | GAL | 809050000 | 2 | PDS | SDS |
GLOSS | GAL | 809000000 | 2 | PDS | SDS |
Testing Method | ||||
---|---|---|---|---|
Resin type | Urethane/Acrylic | |||
Solvent | Water, 2-Methoxymethylethoxypropanol, Dimethylethanol Amine, 1-methyl-2-Pyrrolidone | |||
Odor | Mild Amine | |||
Luster (@ 60°) |
| ASTM D 523 | ||
| ASTM D 523 | |||
| ASTM D 523 | |||
No. of coats | 2 – 3 | |||
Dry-time |
| ASTM D 1640 & | ||
| Gardner circular | |||
Dry film thickness | 0.6 mil/coat | |||
Flash point | >212°F (SETAFLASH*) | SETAFLASH* | ||
> | ASTM D 3828 | |||
Applicator | Natural bristle or foam brush, lambswool or synthetic pad | |||
VOC (grams/liter) | 250 maximum Part A, 275 maximum Crosslinked | ASTM D 3960 | ||
Coverage (sq. ft/gal) | Approx. 500-600 | |||
% Solids | 33.0 – 36.0 Crosslinked | ASTM D 2369 | ||
Pounds/gallon | 8.64 – 8.69 | |||
pH | 7.00 – 9.00 | |||
Viscosity (centipoises) | 55 – 100 |
This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
Use only with adequate ventilation. To avoid overexposure, open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches, or dizziness, increase fresh air, or wear respiratory protection (NIOSH approved) or leave the area. Avoid contact with eyes and skin. Wash hands after using. Keep container closed when not in use. Do not transfer contents to other containers for storage.
At Decades Flooring, our Flooring Contractors respect our clients, their budget and work collaboratively to identify the best products fit their project. Flooring Experts at Decades Floors has over 10 years of professional experience installing floors throughout Los Angeles and surrounding areas.